This flow meter has low flow capabilities in a wide range of flow processes and is mainly developed
to perform an accurate and repeatable flow measurement.
Distinguished results in measuring chemicals, fuel, additives and more. These devices are suitable for long-term measurements without losing accuracy.
Characteristics | 0045 | 0085 |
---|---|---|
Inner diameter in mm | 4,7 | 9,3 |
Flow range | 0,03 – 2 L/min | 0,3 – 20L/min |
Accuracy | 1% of reading | 1% of reading |
Repeatability | <0,15% | <0.15% |
Wetted Materials | PVDF / Ruby | PVDF / Ruby |
Tube connection | 7mm hose barb | 12 mm hose barb |
Tube length in mm | L max 53 | L max 62 |
Liquid temperature in °C | -20 to +80 | -20 to +80 |
Max. pressure at 20°C in MPa | 2,5 (25 bar) | 2,0 (20 bar) |
Viscosity in cSt. | 0,8 – 10 | 0,8 – 10 |
K factor (water) in pulse/L | 100.000 | 4800 |
Power Supply | 5 – 30 Vdc | 5 – 30 Vdc |
Output signal | 5 – 30 V square wave | 5 – 30 V square wave |
Power consumption | 34 mA at 5V | 34 mA at 5V |
Electrical cable length | PVC 1 meter | PVC 1 meter |